Maintenance of oil extruder

1. It is forbidden to frequently start the main motor of the extruder. The interval between two starts must be greater than 15 minutes. Otherwise, the control cabinet and the motor may be burned.

2. The feeding frequency is strictly prohibited to work under 5Hz for a long time, otherwise it will cause the inverter and feeding motor to burn out.

3. At the same time, sufficient steam should be fed at the same time, otherwise it will cause plugging of the extruder. After the bulking machine is plugged, the outlet template must be opened first. Under the condition of continuous steaming, the manual rolling stock will start the main motor under the condition that the motor can be driven to discharge the jammed material. Otherwise, the outlet barrel needs to be disassembled.

TG Concentrates

Tg Concentrates,Fish Oil 5/25 Tg,5/25 Tg Tg Concentrates,Fish Oil Omega-3

ZHOUSHAN SINOMEGA BIOTECH ENGINEERING CO.,LTD , https://www.sinomegabiotech.com