Mouse Desmin, Des ELISA Kit Usage Principle

Mouse Desmin, Des ELISA Kit Usage Principle

Adapted species: Human, Rat, Mouse, Rabbit
Application: Scientific research test method: Enzyme linked test limit: Research supplier: Shanghai Fanke Biotechnology Co., Ltd. Quantity: 100
Specifications: 96T/48T

Mouse Desmin, Des ELISA Kit Principle of Mouse Deproteinase (Des) ELISA Kit <br>Category: FK-QZ3228
Specification: 96T/48T

Mouse Desmin, Des ELISA Kit Usage Principle

The kit was a solid phase sandwichenzyme-linked immunosorbent assay (ELISA), and the AVP concentrations of the standard samples and unknown concentrations of samples were detected by the addition of microporous enzyme plates.. At the same time, the AVP and the biotin labeled antibodies were incubated At the same time..After washing, the addition of Pro labeled HRP. After the warming and washing, the removal of the non binding enzyme conjugate, and then added to the substrate a, B, and the enzyme conjugate at the same time.Produce color The color depth and the concentration of AVP in thesample was proportional to the concentration of the sample..

Operation notes
1 reagent should be stored in the label manual, before using to roomtemperature. The standard after dilute dilute should be discarded, donot save.
2 the experimental plate should be immediately put back in the bag,seal the preservation, lest metamorphism.
3 no other reagents should be packaged or well. Do not mix differentbatches of reagents. Use before the shelf.
4 use a disposable suction head lest cross contamination, draw thetermination liquid and substrate B, a liquid, to avoid using the metalpart of the sample.
5 use clean plastic containers to configure the washing liquid. Allsamples of ingredients and mix well before use in the kit.
6 wash the enzyme plate should be fully dry, do not absorb water paperdirectly into the enzyme labeled pores in the water absorption.
7 substrate a should be volatile, to avoid prolonged open lid.Substrate B is sensitive to light, avoiding prolonged exposure to light.To avoid contact with hand, toxic. After the experiment, read the ODvalue immediately..
8 add reagents should be consistent in order, to ensure that allreaction plate hole incubation time.
9 to carry out the temperature fertility operation according to the time, the amount and the order of the liquid added in the instruction manual.

Kit performance:
1 the correlation coefficient r value of linear regression and the expected concentration of sample was 0.92 above.
The 2 batch and the batch should be less than 9% and 15% respectively.
Detection range:
1.5 -90 g/ml g/ml
Save condition and its validity:
1 reagent kit preservation: 2-8.
2 validity: 6 months
Mouse desmin (Des) ELISA kit

Tips: Not for clinical treatment.

PVC Gloves

Disposable PVC gloves For Housework, factory protection in electronics, chemical industry, aquaculture, glass, food, etc., hospitals, scientific research and other industries; widely used in semiconductor, precision electronic components and instrument installation and operation of sticky metal utensils, high-tech product installation and debugging, Disc drives, composite materials, LCD display tables, circuit board production lines, optical products, laboratories, hospitals, beauty salons and other fields.

Pvc Gloves,Black Pvc Gloves,Long Pvc Gloves,Polyvinyl Gloves

Jiangsu Asbao Medical Technology Co., Ltd. , https://www.iigloves.com